The route diagram, socket positions, and cable and material quantities calculated from the plan.
We work from the floor plan and the seating layout. Without them the estimate is guesswork and redoing it is expensive.
The route diagram, socket positions, and cable and material quantities calculated from the plan.
In rented premises the work requires the owner's written permission.
Trunking, trays, conduit. Above the suspended ceiling or along the walls in cable channel.
Sockets at the desks, patch panels in the cabinet, labels at both ends of every line.
Every line is tested with an instrument and a printout, not on the principle that it seems to work.
A numbered drawing: which socket is wired to which panel port.
An office of fifty workplaces is installed in a week. The drawings and approvals take about the same.
We visit, measure and work out the routes and where the cabinet goes.
The diagram, the bill of materials, the quote. All agreed before anything is bought.
We run the routes, install and terminate. Better done before the furniture goes in.
Test printouts, the diagram, labelled ports.
Two sockets per workplace is the norm, not a luxury. The second goes to a phone, a printer, a second computer, or simply saves the day when the first stops working. Adding a port after handover costs more than running it at the start: the trunking is closed and furniture stands on top.
For an ordinary office category five is enough: it gives a gigabit and costs less. Category six makes sense on long runs, where ten gigabits is planned and in the server room. The installation cost differs little, so on new sites people usually go straight to six.
For portable devices it is enough. But fixed workstations, server hardware, cameras and printers get both stability and speed from copper cabling. Saving on the cabling looks like a good decision right up to the day the complaints about dropped connections start.
They prove that the installed line meets the declared category on every parameter rather than merely passing data somehow. A year later, when unexplained faults appear, that paperwork is the only way to clear the cabling of suspicion.
Send the floor plan and say how many workplaces are planned. We will visit the site and prepare the design along with a costing.